Home » Products » Fire Protection Piping » OS&Y Gate Valves

OS&Y Gate Valve Supplier

Flanged rising-stem valves with the operating clearance defined

We supply flanged OS&Y gate valves for wholesale fire-water orders and project valve schedules. The selected valve keeps its face-to-face length, full stem-travel envelope and flange arrangement together. A required supervisory switch and the project approval records are included as named submittal items.

Connection
Flanged
Operation
Handwheel, rising stem
Shown sizes
2–6 in. / DN50–150
Shutoff element
Resilient wedge

Flanged OS&Y valve supply

Valve formOutside screw and yoke gate valve with rising stem
ConnectionFlanged ends; selected series uses ANSI B16.1 Class 125 drilling
Operating methodManual handwheel
Valve positionVisible stem position; switch arrangement when ordered
Protective finishEpoxy-coated body, with surface requirements on the selected valve
SubmittalSelected model, pressure/temperature rating, drawing and required approval evidence

OS&Y face-to-face length and stem travel

Compare the valve body length and the complete height envelope with the riser arrangement.

Size (in.)DNFace-to-face L (mm)Hmin (mm)Hmax (mm)
250178348400
2-1/265190373440
380203408490
4100229471573
5125254541665
6150267601755

No matching specification. Clear the search to see every row.

Scroll sideways to see every column.

Selected V3101–V3106 flanged OS&Y catalog dimensions. Hmin and Hmax are the minimum and maximum overall valve heights; allow additional operating and maintenance access. The pressure and temperature rating is identified on the selected valve submittal, separately from flange drilling.

Valve ratings and project approval

Flange drilling and valve rating

ANSI B16.1 Class 125 identifies the selected flange connection. The valve submittal separately states its working-pressure rating and service conditions so both connection geometry and pressure requirements are matched.

The exact listed configuration

Orders requiring UL Listing or FM Approval use the actual approval record for the supplied manufacturer, model, size and rating. The applicable evidence stays with that selected configuration in the project submittal.

Design and coating references

The adopted valve and coating specifications define different acceptance requirements. The submittal names the applicable product design, finish and inspection scope for the supplied series.

Flange fit, stem clearance and switch interfaces

Face-to-face replacement

A replacement valve must match the gap in the existing pipework as well as its nominal size. The L dimension and gasket arrangement determine whether the flange joint can be assembled without altering the spool.

Handwheel access

The layout needs space around the wheel and above the moving stem. Wall proximity, nearby pipework and overhead members can restrict an otherwise correct valve selection.

Supervisory switch

A stem switch is a separate assembly with its own bracket, actuator travel and electrical requirements. The order identifies whether the valve is supplied switch-ready or with the specified switch installed.

Gasket-face compatibility

The approved connection detail coordinates the mating flange face, gasket and bolting arrangement. We match the supplied valve flange to that complete joint detail alongside its nominal size.

OS&Y valves for risers and isolation points

Fire-water riser schedules

A clear visible stem position supports valve status checks. Each riser item can retain its size, connection, monitoring requirement and approved product configuration in the same valve schedule.

Replacement isolation valves

Replacing an existing OS&Y valve starts with the complete installed envelope. The open height, flange spacing and switch interface are as important as the pipe size when the surrounding equipment remains in place.

Valve geometry and release checks

OS&Y valve beside a straightedge and caliper on a bench

Stem and handwheel operation

The operating check covers travel, visible position and unobstructed handwheel movement. The inspection scope also checks the stem and yoke for handling damage.

Connection dimensions

Face-to-face length, flange arrangement and the selected height envelope are compared with the submittal drawing. Different valve series can have different dimensions at the same nominal size.

Body, seat and closure tests

Required pressure and closure test records follow the selected product standard and purchase specification. Test pressure is identified as a test condition, separately from working pressure.

Coating and identification

Connection faces and coated surfaces are inspected before protectors are fitted. The valve identity remains connected to the material, test and approval documents required by the order.

OS&Y valve submittal and release records

Selected model drawingRequired product approval evidenceSpecified pressure and closure test recordsValve quantity and packing list

Protecting the operator and flange faces

Supported valve bodies

Timber blocking carries the valve body during shipment. Stems, handwheels and switch brackets remain protected and clear of hard crate contact.

Connection-face protection

Clean protectors keep the flange faces and waterway free from loose packing material. Separate accessories are identified so the receiving team can reconcile switches, fasteners and valves.

Valve and accessory quote lines

Our offer identifies the valve series, dimensions and rating, followed by the required switch and release documents. Quantity, packing and destination terms are tied to that same configuration.

OS&Y Gate Valves purchasing questions

Can the rising stem be shortened to fit below a beam?

The supplied stem length forms part of the valve operating mechanism and selected configuration. Where overhead space is limited, the approved valve arrangement must accommodate its complete open envelope and retain that specified mechanism.

Should the replacement gap be measured with the old gaskets included?

The catalog L dimension is the valve’s face-to-face length. The installed connection also contains the gasket stack. Record the exposed mating-flange faces and the specified gasket arrangement separately so the replacement body is compared using the same datums.

Does Class 125 flange drilling mean a 125 psi valve rating?

Class 125 identifies the flange connection geometry. The supplied valve model has its own stated working-pressure rating for the service conditions; both requirements are checked in the submittal.

Is the supervisory switch included?

The offer states whether the valve is switch-ready or supplied with the specified supervisory switch and bracket installed. The switch assembly has its own identified supply line and configuration.

Can the valve be used for continuous throttling?

This gate-valve supply is for isolation. A continuous regulation requirement uses a valve selected for control duty at the actual flow conditions.

Does every valve on this page carry the same UL or FM coverage?

Approval coverage is specific to the actual manufacturer, model, size and rating. An order requiring it includes the applicable approval evidence in the selected valve submittal before acceptance.

Working through this order

We wrote these for buyers specifying and receiving exactly this kind of package.

Quote your OS&Y valve schedule

Send the nominal size, required valve rating, flange detail, available opening clearance and quantity. Include the switch requirement, project approval criteria and destination. We return the selected valve drawing and a clear list of included accessories and documents.

Metdax
Get a quote
Search Metdax

Language

Get a factory quote

Send your specifications or attach a material list.

OS&Y Gate Valves

Your information is used to respond to this inquiry. Privacy policy

sales@metdax.com

+86 177 7599 6440