Home » Products » Fire Protection Piping » NRS Fire Gate Valves

NRS Fire Gate Valve Supplier

Non-rising-stem isolation valves with an identified operating interface

Our fire-water valve supply includes flanged non-rising-stem gate valves for wholesale and project orders. The rotating stem operates within the valve’s fixed external envelope. Handwheel, operating-nut and position-indication requirements are identified with the selected valve assembly, alongside its flanges and project submittal.

Stem form
Non-rising
Connection
Flanged
Duty
Fire-water isolation
Operator
Selected assembly

NRS Fire Gate Valves in our supply

Valve formFlanged gate valve with non-rising stem
Shutoff dutySelected fire-water isolation service
Operator selectionHandwheel or accepted operating interface on the selected model
Position indicationIdentified local indicator or specified remote monitoring assembly
Installed envelopeFixed external stem envelope plus operator and maintenance access
Submittal identityActual manufacturer, model, size, rating and required product records

NRS valve length and handwheel-envelope reference

A non-rising stem retains a fixed external stem height. The selected manufacturer reference below shows why body length and complete handwheel envelope are still separate fit checks.

Reference size (in.)DNFace-to-face L (mm)Overall H (mm)
250150282
2-1/265170290
380180331
4100190366
6150210490
8200230560

No matching specification. Clear the search to see every row.

Scroll sideways to see every column.

Rapidrop 117FF F4 flanged NRS reference dimensions, EN 558 series 14. These are that model’s L/H dimensions. Our selected offer retains its own body length, operator envelope and flange drawing for the scheduled installation.

NRS operation and monitored isolation

Rotating stem, internally moving gate

The operator rotates the retained stem and moves the gate through its internal travel. The selected mechanism and seat assembly establish the isolation function and operating instructions.

Local indication or an indicator post

Handwheel indication and a post-operated installation use different interfaces. A post arrangement is accepted with its mounting plate, shaft coupling and operating travel matched to the selected valve.

Fire-service product evidence

UL 262 covers gate valves used in fire-protection service, including non-rising-stem forms. Required listing or approval records identify the actual supplied valve and any separately specified indicator equipment.

Operator access and indicator interfaces

Body length at a replacement joint

The exposed mating-flange gap is compared with the selected valve L dimension and gasket stack. A compact stem arrangement can still require a different spool length from the existing gate valve.

The handwheel needs a working arc

The external stem top remains stationary, while the handwheel needs clear space for operation. The installed drawing includes nearby walls, pipework and the access needed to remove the bonnet or operator.

Post mounting and shaft engagement

A post-equipped installation retains the valve mounting pattern, coupling engagement and shaft length in one accepted detail. The post’s target-setting procedure is linked to the actual valve travel.

NRS valves in fire-water purchasing schedules

Compact isolation stations

A fixed stem-top envelope suits layouts that allocate the selected operator height at an isolation point. Valve tags retain the normal position and the required local or supervised indication.

Post-operated locations

For an accepted post installation, the valve item and post equipment share the same operating reference. The civil layout establishes ground level, valve depth and accessible post position.

NRS valve operation and receiving records

Flanged NRS valve beside loose dimensional tools on a clean inspection bench

Full internal travel

The prescribed operating check follows the selected valve through its stroke. The record identifies the opening direction, end positions and the operating assembly used during that check.

Indicator correspondence

Where included, local targets or supervisory equipment are checked against the actual open and closed positions. Their model and settings remain traceable to the valve tag.

Seat, body and connection

Required shell and closure records identify test conditions and acceptance. Dimensional checks retain the flange arrangement and operator envelope of the same valve model.

NRS Fire Gate Valves supply records

Selected NRS drawingOperator and indication detailsRequired shell/closure recordsValve and accessory list

Valve bodies supported, operators protected

Body-supported crating

Blocking carries the cast body and protects its machined flange faces. The wheel, indicator and gland remain clear of packing restraint loads.

Matched operating groups

Post plates, shafts, couplings and monitoring items are packed with their valve references where ordered. The list distinguishes a complete operating group from loose replacement parts.

An explicit operating-equipment price

Our offer states the selected valve and required records, followed by included operator or indication equipment. Quantities, packing and destination terms apply to that defined assembly.

NRS Fire Gate Valves purchasing questions

How is an NRS valve’s open position verified?

The selected assembly provides its identified local indicator or position-monitoring equipment. Its target or contacts are set against the actual gate travel according to the model instructions, then retained with the valve tag.

Can an OS&Y stem supervisory switch be reused on an NRS valve?

The switch mounting and sensing method are matched to the NRS operating arrangement. A rising-stem travel switch and a stationary-stem indicator use different interfaces; our offer identifies the compatible monitoring equipment for the selected valve.

Does a handwheel valve automatically accept an indicator post?

Post operation is accepted against the valve’s mounting and drive interface. The plate pattern, coupling, shaft engagement and travel-setting method identify the complete valve/post arrangement.

Which opening direction is supplied?

The selected operating assembly retains its specified opening direction and marking. Existing site direction requirements are kept with the valve tag so replacement and new equipment follow the same approved operating convention.

Can the handwheel be used to regulate flow continuously?

The NRS gate valve is selected for isolation. A flow-regulation duty is quoted with a control valve whose trim and capacity match the required operating conditions.

What is needed to quote a replacement operating shaft?

The valve and indicator references establish the coupling ends and engagement. The installed valve-to-post geometry supplies the shaft length, including any accepted intermediate support and adjustment allowance.

Related guides and order tools

Quote your NRS valve schedule

Send the nominal sizes, pressure requirements, flange details and quantities. Include the desired operator, indication or post interface, normal position and project approval criteria. We return the selected NRS drawing and a counted operating-equipment offer with shipment terms.

Metdax
Get a quote
Search Metdax

Language

Get a factory quote

Send your specifications or attach a material list.

NRS Fire Gate Valves

Your information is used to respond to this inquiry. Privacy policy

sales@metdax.com

+86 177 7599 6440