Home » Products » Pipe Fittings, Valves & Pumps

Pipe Fittings, Valves & Pumps product range

Pipe Fittings, Valves & Pumps Supplier

Grooved, welded and threaded connections, industrial valves and centrifugal fire-water pumps.

Source grooved, threaded and butt-weld fittings, flanges, industrial valves and fire-water pumps. Compare the connection first, then the material, operating duty and installation space.

Grooved, butt weld and threaded fittingsCarbon and stainless steel slip-on flangesGate, ball and butterfly valve selectionCentrifugal pumps for fire-water supply

Browse Pipe Fittings, Valves & Pumps

6 products
Carbon steel butt weld elbow, equal tee and concentric reducer

Butt Weld Pipe Fittings

Choose carbon steel elbows, tees and reducers by weld-end size, wall thickness and installation dimensions.

Elbows / teesConcentric / eccentric reducers
View Product
Threaded steel elbow, equal tee, full coupling and cap

Threaded Pipe Fittings

Specify threaded steel fitting patterns and the mating thread designation before comparing dimensions.

NPT thread matchingElbows / tees / couplings
View Product
Steel slip-on flanges showing gasket face and short rear hub

Pipe Flanges

Select carbon or stainless steel slip-on flanges with the required class, facing and bolt pattern.

Carbon / stainless steelClass 150 / 300
View Product
Flanged ball, gate and butterfly valves with manual operators

Industrial Pipe Valves

Compare ball, gate and butterfly valves around isolation duty, body and seat materials, and operator clearance.

Ball / gate / butterflyMaterial and operator selection
View Product
Horizontal single-suction and vertical inline centrifugal pump units

Fire Water Pumps

Single-stage and vertical inline fire-water pumps selected by flow, head, drive and installation arrangement.

Fire-water dutyFlow & head
View Product

Fittings, Valves and Pump Selections

Start with the mating connection

Grooved, butt-weld, threaded and flanged joints use different mating geometry. Within each family, elbows change direction, tees introduce branches and reducers join unequal sizes. Their two or three connection sizes remain distinct on the purchase line.

  • Grooved: actual OD and groove profile
  • Butt weld: end OD and wall thickness
  • Threaded or flanged: designation and mating geometry

Carry service conditions into material selection

Fluid, pressure and temperature determine material, gasket and valve-seat requirements. A part can physically fit a connection yet be unsuitable for the service. Metal grade, seal and applicable component rating therefore stay with the selected construction.

  • Identify fluid and temperature range
  • Specify metal grade and wetted materials
  • Review gasket and seat compatibility

Choose valves around operation and access

Ball, gate and butterfly valves differ in isolation behavior, construction and clearance needs. Operating frequency, body length and operator access distinguish the model choices; nominal size alone cannot specify the installed valve.

  • State the operating function
  • Check body length and operator clearance
  • Identify body, seat and connection requirements

Select a fire-water pump by its duty point

A fire-water pump is selected around flow and head, suction conditions and power supply. Single-suction and vertical-inline layouts occupy different installation spaces. The quoted pump, driver and controller remain separate equipment items so the package can be compared with the project schedule.

  • Give flow and head with units
  • State suction conditions and supply frequency
  • Identify pump, driver and controller scope
Connection information for the component families
ConnectionMating informationOpen the product page for
GroovedActual OD, groove profile and coupling systemRigid or flexible couplings, fittings and gaskets
ThreadedThread standard, gender and sizeNPT/BSP product distinctions and fitting geometry
Butt-weldOD, wall, bevel and fitting dimensionsElbows, tees and reducers
FlangedDrilling standard, size, facing and pressure classFlanges and flange-ended valves
Fire-water pumpFlow, head, drive and suction/discharge arrangementSingle-stage and vertical inline pump choices

Scroll sideways to see all table columns.

Component Sizes, Materials and Ratings

ASME B16.9Wrought butt weld fittingsASME B16.9 covers factory-made wrought butt-welding fitting dimensions and associated requirements. Pattern, material and weld-end wall identify the actual elbow, tee or reducer being purchased.
ASME B16.11Forged threaded fittingsDistinguishes forged threaded fittings in Classes 2000, 3000 and 6000 from socket-welding classes. A fitting class is a designation used with the applicable design rules, not a universal working pressure in psi.
ASME B1.20.1US pipe thread designationsASME B1.20.1 defines general-purpose inch pipe threads and gauging requirements, including NPT. A same-size BSP thread is a different mating designation.
ASME B16.5Flange class, drilling and facingASME B16.5 connects flange dimensions with material and pressure-temperature requirements. Class, grade and facing belong together; Class 150 and Class 300 have different drilling and are not fixed psi ratings.
NFPA 20Fire pump installation requirementsNFPA 20 addresses stationary fire-protection pumps. The project’s adopted edition and equipment requirements govern review of the proposed pump, driver and controller; the standard name alone does not identify an accepted package.

Component and Equipment Supply Options

Item schedule and material review

Our quote separates fitting patterns, materials and connections by item. Reducer and branch sizes, valve operators and pump accessories retain their own scope rather than being hidden in one equipment description.

Fitting and flange preparation

The fitting pattern, weld end, thread or flange drilling determines the forming and machining scope for the selected component. Its mating pipe dimensions remain part of that preparation.

Surface finish and end protection

Finish and corrosion protection follow the ordered item. Sealing faces, threads and weld ends need their own handling protection so packing does not damage the prepared connection.

Valve and pump configuration

Valve configuration includes its operator and seat. A pump package identifies the pump, drive and connection arrangement, with controllers and other accessories listed separately.

Inspection records and packing

The accepted order identifies the dimensional, material and equipment records required for its components. Item marks and package numbers connect those components to the BOM and packing list.

Component Inspection and Package Contents

Four acceptance priorities

Item identityMatch the fitting pattern, size, material and component model to the approved item schedule.
Connection geometryCheck the ordered threads, weld ends, grooves or flange drilling against the mating requirements.
Operating configurationVerify valve operator and seat selection, or pump duty, drive and connection data.
Traceable packingKeep item marks, protected connections and package quantities consistent with the packing list.

Specify the records needed for acceptance

  • Approved item schedule with material, size and connection designations
  • Material test records for the components requiring them
  • Dimensional records for specified ends, threads and flange drilling
  • Valve data sheets and agreed inspection or test records
  • Pump curve and equipment data for the selected speed, driver and accessories
  • Packing list, item marks and shipment identification

Questions about mixed component orders

What should I send for an old part with no readable marking?

Send photographs, measured connection dimensions and a sketch showing the installation space. Include the fluid and operating conditions. Measurements can narrow the options, but the mating specification and material requirements still need to be established before a replacement is ordered.

Does a pump enquiry need a motor horsepower selection?

A known horsepower can be included, but flow, required head, suction conditions and power supply are the starting information. Motor selection follows the proposed pump curve and operating requirements. State voltage, phase and frequency so the drive configuration can be evaluated with the pump.

Are spare seals and gaskets quoted against the installed model?

Yes. Valve and pump spares are identified by the selected model and construction. Fitting gaskets retain the coupling family and service material rather than being selected by nominal size alone.

Get a quote for your piping component list

Send the product types, sizes, materials, connection details, quantities, service conditions and destination. Add valve operators or pump flow, head and power requirements where relevant. A typed list or marked drawing is enough to start the order review.

  • Itemized components and equipment scope
  • Material, connection and document requirements
  • Packing, delivery terms and production schedule
METDAX
Get a quote
Search METDAX

Language

Get a factory quote

Send your specifications or attach a material list.

Your information is used to respond to this inquiry. Privacy policy

ruofan1901@gmail.com